Pressure-balance Valves

It is normal for a minimal amount of water that remains in the pipes to drip form the shower head after shutting off the valve. The dripping can last as long as three minutes to enable the water in the pipes to drain. If dripping lasts for longer than three minutes, one of two problems likely has occurred. One option is the mechanical stop is not set properly causing the cartridge to remain partially open. A second option is that the cartridge needs to be replaced.
  • DO NOT apply extreme force on the handle to stop dripping
  • Some pressure-balanced valves have internal filters to protect the cartridge. If these filters become clogged, water flow will decrease. The filters can be easily cleaned. Refer to the installation instructions
  • In hard water locations, remove the pressure-balancing cartridge and soak it in white vinegar to remove mineral deposits
  • A small stream of water may come from the tub spout of some pressure-balanced valves when set to the shower head. This is normal and cannot be avoided.